Primena EDA metodologije u cilju sagledavanja stanja izolacionog sistema obrtnih mašina
aUniverzitet u Beogradu, Elektrotehnički institut 'Nikola Tesla', Beograd + Univerzitet u Beogradu, Elektrotehnički fakultet, Beograd
bUniverzitet u Beogradu, Elektrotehnički institut 'Nikola Tesla', Beograd

e-adresa: denis.ilic@ieent.org

Projekat

Povecanje energetske efikasnosti, pouzdanosti i raspoloživosti elektrana EPS-a utvrdivanjem pogonskih dijagrama generatora i primenom novih metoda ispitivanja i daljinskog nadzora (MPNTR - 33024)

Sažetak

Izolacioni sistemi snažnijih obrtnih mašina se već dugi niz godina podrobnije ispituju metodama koje su konstantno unapređivane i potvrđene. Mašine manjih snaga i, uslovno rečeno, manjeg značaja, kao što su visokonaponski motori, su često održavani minimalnim sredstvima i neretko ne podležu ozbiljnijim električnim ispitivanjima. Uvođenjem EDA (Electronic Dielectric Analyzer) metodologije u praksu stvaraju se uslovi za pouzdanu i potpuniju dijagnostiku stanja statorskih namotaja velikih mašina, kao i brz, jednostavan i jeftin 'screening' velikog broja mašina manjih snaga kao što su visokonaponski motori. U radu će biti prikazana EDA metodologija i mogućnosti koje pruža, kao i mogućnosti softverskog i hardverskog rešenja.

Ključne reči

ispitivanje obrtnih mašina; EDA metodologija; dijagnostika stanja; 'screening'

Reference

*** (2002) IEEE Recommended practice for insulation testing of AC electric machinery (2300 V and above) with high direct voltage. IEEE Std 95-2002 (Revision of IEEE Std 95-1977), vol. no. pp.1-56, April 12 doi: 10.1109/IEEESTD.2002.93574
*** (2014) IEEE Recommended practice for testing insulation resistance of electric machinery. IEEE Std 43-2013 (Revision of IEEE Std 43-2000), pp. 1-37, March
*** (1977) IEEE guide for insulation maintenance of large alternating-current rotating machinery (10, 000 kVA and larger). ANSI/IEEE Std 56-1977, vol. no. pp.1-24, March 15, doi: 10.1109/IEEESTD.1977.120246
*** (1999) IEEE guide for operation and maintenance of hydro-generators. IEEE Std 492-1999, vol. no. pp.1-70, Feb. 19 doi: 10.1109/IEEESTD.1999.89194
*** (2009) Generator maintenance: Inspection and test programmes. Paris: CIGRÉ, TB 386, (21 rue dArtois, 75008)
*** (2013) TB 522: Generator stator winding stress grading coating problem
*** SRPS EN 60034 (Serija standarda)
*** EDA III (Electronic Dielectric Analyser): User manuel
Say, M.G. (1976) Windings in alternating current machines. Edinburgh, UK: Pitman Publishing, 4th ed. First published, ch. 3, pp. 63-113
Schlögl, S., Lenko, D. (2014) High-voltage insulation with enhances delamination resistance. Society of Plastic Engineers (SPE), doi: 10.2417/spepro.005620
Tabernero, A., Batle, B., Lopez, L.M., Villarubia, A., Rodriguez, S., Martinez, O. (2008) EDA test to perform predictive maintenance in relevant rotating machines. CIGRE, A1-107
Tabernero, A., Batle, B. (2007) Predictive maintenance in hydrogenerators. u: Hydro
Tavner, P., Ran, L., Penman, J., Sedding, H. (2008) Condition monitoring of rotating electrical machines. London, UK: Institution of Engineering and Technology