Determination of turbine relative efficiency in SHPP
aUniversity of Belgrade, Electrical Engineering Institute 'Nikola Tesla'
bJP EPS Ogranak 'HE Đerdap', Kladovo
cELNOS BL, Banja Luka, BiH

e-mail: dane.dzepceski@ieent.org

Project

Energy efficiency Improvement of Hydro and Thermal power plants in EPS by development and implementation of power electronics based regulation and automation equipment (MESTD - 33020)

Abstract

To assess the fulfillment of contract conditions for the equipment delivery, determining the properties and capabilities of a generating unit or some part of it, the measurements carried out under real operating conditions were necessary. In this paper, the results of the test that was carried out in a small hydropower plant (SHPP), aimed at determining the relative efficiency of the hydraulic turbine and its comparison with the guaranteed values, are presented. The dependence of the turbine efficiency on the turbine discharge was determined based on the test results, using the index method. The test was performed at one net head.

Keywords

References

*** (2010) IEC62006:2010 Hydraulic machines: Acceptance tests of small hydroelectric installations. edition 1.0, 28.10
*** (2017) Izveštaj o ispitivanju turbine kućnog agregata HE Bočac. Elaborat 217057, 29.9