Vojnosanitetski pregled
2014, vol. 71, br. 10, str. 969-971
jezik rada: engleski
vrsta rada: prikaz slučaja
doi:10.2298/VSP1410969D


Uspešno izvlačenje odljuštenog spoljašnjeg sloja dijagnostičke koronarne žice J-tipa iz leve poplitealne arterije tokom elektivne koronarne angiografije
aClinical Center of Niš, Clinic for Cardiovascular Diseases, Niš
bClinical Center of Kragujevac, Clinic for Cardiology, Kragujevac

e-adresa: miodragd@ptt.rs

Sažetak

Uvod. Blokiranje i fraktura dijagnostičkih ili terapijskih sredstava unutar koronarne cirkulacije je redak, ali rastući problem. Prikaz bolesnika. Muškarac, star 70 godina, primljen je u našu kliniku zbog koronarne angiografije pre planirane zamene aortnog zaliska. Arterijski uvodnik je najpre postavljen u desnu zajedničku femoralnu arteriju. Posle uvođenja J-tipa dijagnostičke koronarne žice vodiča u aortu i navlačenja levog Judkins dijagnostičkog katetera preko žice, iznenada je došlo do odljuštenja hidrofilnog sloja žice na nivou aortnog luka. Vrlo brzo ovaj spoljni omotač žice nošen krvnom strujom ušao je u levu femoralnu arteriju, a onda u levu poplitealnu arteriju. Odljušteni deo koronarne žice je uspešno uhvaćen i izvučen napolje korišćenjem katetera u obliku guščjeg vrata. Zaključak. Iznenadno odljuštenje spoljašnjeg sloja dijagnostičke hidrofilne koronarne žice sa J-vrhom tokom koronarne angiografije moguće je rešiti brzo i uspešno pomoću običnog katetera.

Ključne reči

Reference

Alexiou, K., Kappert, U., Knaut, M., Matschke, K., Tugtekin, S.M. (2006) Entrapped coronary catheter remnants and stents: must they be surgically removed?. Tex Heart Inst J, 33(2): 139-42
Ammann, P., Brunner-la, R.H.P., Angehrn, W., Roelli, H., Sagmeister, M., Rickli, H. (2003) Procedural Complications Following Diagnostic Coronary Angiography Are Related to the Operator's Experience and the Catheter Size. Cathet Cardiovasc Intervent, 59: 13-1
Chang, T.M., Pellegrini, D., Ostrovsky, A., Marrangoni, A.G. (2002) Surgical management of entrapped percutaneous transluminal coronary angioplasty hardware. Tex Heart Inst J, 29: 329
Criado, F.J. (1999) Percutaneous arterial puncture and endoluminal access techniques. u: Criado F.J. [ur.] Endovascular Intervention: basic concepts and techniques, NY, Armonk: Futura Publishing Company, Inc, : 21-29
Erglis, A., Narbute, I., Sondore, D., Grave, A., Jegere, S. (2010) Tools and techniques: coronary guidewires. EuroIntervention, 6: 1-8
Goksin, I., Baltalarli, A., Semiz, E., Gurses, E., Sacar, M., Ozcan, V., Sungurtekin, H. (2007) Catheter entrapment during balloon angioplasty in patient with in-stent restenosis: an unusual complication and its surgical management. J Card Surg, 22(2): 160-2
Hosokawa, K., Nakajima, Y., Matsuyama, H., Shibasaki, M. (2008) Intraoperative monitoring of movement of an entrapped coronary guidewire by transesophageal echocardiography. Anesthesia and analgesia, 107(4): 1158-60
Kaplan, S., Kaplan, S.T., Kutlu, M. (2010) An unusual case of guide wire fractured during primary percutaneous coronary intervention, and two year follow-up. Kardiologia polska, 68(11): 1291-3
Karabulut, A., Daglar, E., Cakmak, M. (2010) Entrapment of hydrophilic coated coronary guidewire tips: which form of management is best?. Cardiol J, 17: 104
Sheth, R., Someshwar, V., Warawdekar, G. (2007) Percutaneous retrieval of misplaced intravascular foreign objects with the Dormia basket: an effective solution. Cardiovasc Intervent Radiol, 30(1): 48-53