2003, vol. 2, iss. 1, pp. 40-44
|
Super heater state estimation
Procena stanja pregrejača
Termoelektro AD, Beograd
Abstract
Reliability and safety of the drive greatly depends on the thermal energy unit integral parts state. This work deals with the methods techniques and conditions of snake steam superheaters and disgnostic evaluation and state i.e. operating life left assessment.
Sažetak
Smanjenje pouzdanosti i sigurnosti pogona u mnogome zavisi od stanja sastavnih elemenata termo-energetskog bloka. U ovom radu opisane su metode tehnike i uslovi oštećenja zmijastog pregrejača pare i dijagnostičko ocenjivanje i procenjivanje stanja tj. preostalog radnog ceka.
|
|
|
References
|
30
|
Adamović, Ž. (2001) Tehnička dijagnostika. Beograd: OMO
|
4
|
Šćepanović, S. (1999) Dijagnostičke metode u konvencionalnim parnim elektranama. in: JUMO, Herceg Novi
|
3
|
Šćepanović, S. (2000) Praćenje stanja postrojenja za održavanje u radu. Održavanje mašina i opreme - OMO, vol. 29, br. 7-8, str. 322-324
|
5
|
Šćepanović, S., Šipetić, M. (2001) Ekspertni sistemi za inspekciju energetskih sistema i planiranje remonta. Vrnjačka Banja: DQM
|
2
|
Šćepanović, S., Vučeljić, D. (2002) Dijagnosticiranje i održavanje u termoblokovima. Tehnička dijagnostika, vol. 1, br. 1, str. 39-42
|
1
|
Šćepanović, S. (2002) Dijagnostičko procenjivanje stanja vodeno-parnog sistema bloka termoelektrane. Tehnička dijagnostika, vol. 1, br. 2, str. 53-57
|
|
Šćepanović, S., Vučeljić, D. (2002) Procena stanja termobloka. Tehnička dijagnostika, vol. 1, br. 3, str. 66-71
|
|
Šijački-Žeravčić, V. (1999) Zaostali naponi. Beograd: MF
|
|
|
|