Metrika članka

  • citati u SCindeksu: 0
  • citati u CrossRef-u:0
  • citati u Google Scholaru:[=>]
  • posete u poslednjih 30 dana:11
  • preuzimanja u poslednjih 30 dana:4
članak: 2 od 34  
Back povratak na rezultate
Vojnosanitetski pregled
2017, vol. 74, br. 5, str. 410-419
jezik rada: engleski
vrsta rada: izvorni naučni članak
doi:10.2298/VSP150816226S

Creative Commons License 4.0
Testiranje spojnog smicanja dubokih okluzalnih kompozitnih restauracija postavljenih preko podloge od Dycal, Dycal LC, konvencionalnog ili smolom modifikovanog glas-jonomer cementa
aDepartment of Cariology and Endodontics, Faculty of Dentistry, Sts. Cyril and Methodius University, Skopje, Macedonia
bDepartment of Bioscience Research, College of Dentistry, University of Tennessee, Memphis, TN, USA
cDepartment of Prosthodontics, College of Dentistry, University of Tennessee, Memphis, TN, USA
dDepartment of Paediatric and Preventive Dentistry, Faculty of Dental Medicine, University of Belgrade, Belgrade

e-adresa: civanoff@uthc.edu

Sažetak

Uvod/Cilj. Trajnost zubnih nadoknada može se donekle predvideti vstom adhezivne sposobnosti materijala i može se meriti testiranjem snage adhezije restorativnih materijala i zubnih struktura. Cilj ove studije bio je da se da se testira preklapanje spoja koji povezuje zub i biomehaničku jedinicu i da se uporedi jačina veze okluzalnih kompozitnih ispuna postavljenih u duboke kavitete preko podloge od Dycal, Dycal LC, konvencionalnog ili smolom-modifikovanog glas-jonomer cementa. Metode. Ukupno 150 standardizovanih okluzalnih kaviteta bilo je podeljeno u pet grupa (n = 30): I - kaviteti premazani adhezivom (ExciTE®F) i direktno ispunjeni kompozitom (TetricEvoCeram); II i III - kaviteti sa podlogom od Dycal ili Dycal LC pre postavljanja kompozitnog materijala; IV i V - uzorci sa bazom od Fuji IX ili Fuji II LC (n = 30). Jačina vezivne snage određena je pomoću univerzalne mašine, a način neuspeha (adhezivna, kohezivna, mešovita fraktura) određen je stereomikroskopom. Srednje vrednosti su analizirane pomoću ANOVA testa (p < 0,05), a značajnost razlika između grupa analizirana je Student-ovim t-testom. Rezultati. Jačina vezivne snage (MPa) kompozitnih ispuna u kavitetima bez podloge (23,91 ± 4,54) bila je veća u poređenju sa ispunima postavljenim preko Fuji II LC (17,45 ± 2,74), Fuji IX (8,76 ± 2,57), Dycal LC (13,07 ± 1,84) ili Dycal (6.12 ± 1.28). Zaključak. Smicanje ili pomaknuće okluzalnih kompozitnih ispuna u dubokim kavitetima bez lajnera je veće nego u kavitetima postavljenim preko Fuji II LC > Fuji IX > Dycal LC > Dycal.

Ključne reči

Reference

*** (2003) Dental materials: Testing of adhesion to tooth structure: ISO/TS 11405. [published on 2003 February 1]. Available from: www.iso.org/iso/catalogue_detail.htm?csnumber
Abreu, C.W., Santos, J.F., Passos, S.P., Michida, S.M., Takahashi, F.E., Bottino, M.A. (2011) The influence of cutting speed and cutting initiation location in specimen preparation for the microtensile bond strength test. J Adhes Dent, 13(3); 221-6
Allanigue, C.M., Rapp, R., Piesco, N.P., Elliott, M.A., Nirschl, R.F., Guevara, P.A., i dr. (1986) Adaptation of composite resin restorative materials to retentive grooves of Class I cavity preparations. Pediatr Dent, 8(3); 147-52
Armstrong, S., Geraldeli, S., Maia, R., Raposo, L.H.A., Soares, C.J., Yamagawa, J. (2010) Adhesion to tooth structure: A critical review of “micro” bond strength test methods. Dental Materials, 26(2): e50-e62
Bell, R. B., Barkmeier, W.W. (1994) Glass-ionomer restoratives and liners: shear bond strength to dentin. Journal of Esthetic and Restorative Dentistry, 6(3): 129-134
Bona, Á.D., Pinzetta, C., Rosa, V. (2007) Effect of acid etching of glass ionomer cement surface on the microleakage of sandwich restorations. Journal of Applied Oral Science, 15(3): 230-234
Braga, R.R., Meira, J.B.C., Boaro, L.C.C., Xavier, T.A. (2010) Adhesion to tooth structure: A critical review of “macro” test methods. Dental Materials, 26(2): e38-e49
Braz, R., Sinhoreti, M.A., Spazzin, A.O., Loretto, S.C., Lyra, A.M., Meira-Júnior, S.A.D. (2010) bond strength test using different loading conditions: A finite element analysis. Braz J Oral Sci, 9(4); 439-42
Burger, K.M., Cooley, R.L., Garcia-Godoy, F. (1992) Effect of Thermocycling Times on Dentin Bond Strength bond. Journal of Esthetic and Restorative Dentistry, 4(6): 197-198
Cheung, G. (1990) An in vitro evaluation of five dentinal adhesives in posterior restorations. Quintessence Int, 21(6): 513−6
Davidson, C.L., de Gee, A.J., Feilzer, A. (1984) The competition between the composite-dentin bond strength and the polymerization contraction stress. J Dent Res, 63(12): 1396-9
de Munck, J., Mine, A., Poitevin, A., van Ende, A., van Meerbeek, B. (2010) Testing bond strength: A review of the literature. Dental Materials, 26(2): e139-e140
DeHoff, P.H., Anusavice, K.J., Wang, Z. (1995) Three-dimensional finite element analysis of the shear bond test. Dental Materials, 11(2): 126-131
Dickens, S.H., Kelly, S.R., Flaim, G.M., Giuseppetti, A.A. (2004) Dentin adhesion and microleakage of a resin-based calcium phosphate pulp capping and basing cement. European Journal of Oral Sciences, 112(5): 452-457
Dominguez, M.S., Witherspoon, D.E., Gutmann, J.L., Opperman, L.A. (2003) Histological and scanning electron microscopy assessment of various vital pulp-therapy materials. J Endod, 29(5): 324-33
El-Askay, F.M., Nassif, M.S., Andrade, A.M., Reis, A., Loguercio, A.D. (2012) Effect of surface area and air drying distance on shear strength of etch-and-rinse adhesive. Braz Oral Res, 26: 418-23
Estrela, C., Holland, R. (2003) Calcium hydroxide: study based on scientific evidences. Journal of Applied Oral Science, 11(4): 269-282
Foong, J., Lee, K., Nguyen, C., Tang, G., Austin, D., Ch`ng, C., Burrow, M., Thomas, D. (2006) Comparison of microshear bond strengths of four self-etching bonding systems to enamel using two test methods. Australian Dental Journal, 51(3): 252-257
Fortin, D., Vargas, M.A., Swift, E.J. (1995) Bonding of resin composites to resin-modified glass ionomers. Am J Dent, 8(4); 201-4
Gaengler, P., Hoyer, I., Montag, R. (2001) Clinical evaluation of posterior composite restorations: the 10-year report. J Adhes Dent, 3(2); 185-94
Goracci, G., Mori, G. (1996) Scanning electron microscopic evaluation of resin-dentin and calcium hydroxide-dentin interface with resin composite restorations. Quintessence Int, 27(2): 129-35
Heintz, S.D. (2007) Systematic reviews: I. The correlation between laboratory tests on marginal quality and bond strength. II. The correlation between marginal quality and clinical outcome. J Adhes Dent, 9 Suppl 1: 77-106
Helvatjoglu-Antoniades, M., Koliniotou-Kubia, E., Dionyssopoulos, P. (2004) The effect of thermal cycling on the bovine dentine shear bond strength of current adhesive systems. Journal of Oral Rehabilitation, 31(9): 911-917
Hilton, T.J. (2002) Can modern restorative procedures and materials reliably seal cavities?, In vitro investigations. Part 1. Am J Dent, 15(3); 198-210
Khatri, A., Nandlal, B., Srilatha (2007) Comparative evaluation of shear bond strength of conventional composite resin and nanocomposite resin to sandblasted primary anterior stainless steel crown. Journal of Indian Society of Pedodontics and Preventive Dentistry, 25(2): 82
Khoroushi, M., Rafiei, E. (2013) Effect of thermocycling and water storage on bond longevity of two self-etch adhesives. Gen Dent, 61(3); 39-44
Leloup, G., d`Hoore W., Bouter, D., Degrange, M., Vreven, J. (2001) Concise Review Biomaterials & Bioengineering: Meta-analytical Review of Factors Involved in Dentin Adherence. Journal of Dental Research, 80(7): 1605-1614
Lin, A., Mcintyre, N.S., Davidson, R.D. (1992) Studies on the adhesion of glass-ionomer cements to dentin. J Dent Res, 71(11): 1836-41
McDonough, W.G., Antonucci, J., He, J., Shimada, Y., Chiang, M.Y., Schumacher, G.E., Schultheisz, C.R. (2002) A microshear test to measure bond strengths of dentin-polymer interfaces. Biomaterials, 23(17): 3603-3608
Miyazaki, M., Sato, M., Onose, H., Moore, B.K. (1998) Influence of thermal cycling on dentin bond strength of two-step bonding systems. Am J Dent, 11(3): 118-22
Munksgaard, E.C., Irie, M., Asmussen, E. (1985) Dentin-Polymer Bond Promoted by Gluma and Various Resins. Journal of Dental Research, 64(12): 1409-1411
Murray, P.E., García-Godoy, F. (2006) The incidence of pulp healing defects with direct capping materials. Am J Dent, 19(3); 171-7; 46
Nujella, B.P., Choudary, M.T., Reddy, S.P., Kumar, M.K., Gopal, T. (2012) Comparison of shear bond strength of aesthetic restorative materials. Contemp Clin Dent, 3(1); 22-6
Opdam, N.J., Bronkhorst, E.M., Roeters, J.M., Loomans, B.A. (2007) Longevity and reasons for failure of sandwich and total-etch posterior composite resin restorations. J Adhes Dent, 9(5); 469-75
Pecora, N., Yaman, P., Dennison, J., Herrero, A. (2002) Comparison of shear bond strength relative to two testing devices. Journal of Prosthetic Dentistry, 88(5): 511-515
Peumans, M., Kanumilli, P., de Munck, J., van Landuyt, K., Lambrechts, P., van Meerbeek, B. (2005) Clinical effectiveness of contemporary adhesives: a systematic review of current clinical trials. Dental materials, 21(9): 864-81
Phrukkanon, S., Burrow, M.F., Tyas, M.J. (1998) The influence of cross-sectional shape and surface area on the microtensile bond test. Dental Materials, 14(3): 212-221
Placido, E., Meira, J.B.C., Lima, R.G., Muench, A., Souza, R.M.de, Ballester, R.Y. (2007) Shear versus micro-shear bond strength test: A finite element stress analysis. Dental Materials, 23(9): 1086-1092
Raposo, L.H.A., Armstrong, S.R., Maia, R.R., Qian, F., Geraldeli, S., Soares, C.J. (2012) Effect of specimen gripping device, geometry and fixation method on microtensile bond strength, failure mode and stress distribution: Laboratory and finite element analyses. Dental Materials, 28(5): e50-e62
Salz, U., Bock, T. (2010) Testing adhesion of direct restoratives to dental hard tissue - a review. J Adhes Dent, 12(5); 343-71
Sano, H., Shono, T., Sonoda, H., Takatsu, T., Ciucchi, B., Carvalho, R., Pashley, D.H. (1994) Relationship between surface area for adhesion and tensile bond strength - Evaluation of a micro-tensile bond test. Dental Materials, 10(4): 236-240
Schuurs, A. H. B., Gruythuysen, R. J. M., Wesselink, P. R. (2000) Pulp capping with adhesive resin-based composite vs. calcium hydroxide: a review. Dental Traumatology, 16(6): 240-250
Sinhoreti, M.A.C., Consani, S., de Goes, M.F., Sobrinho, L.C., Knowles, J.C. (2001) Influence of loading types on the shear strength of the dentin-resin interface bonding. Journal of Materials Science: Materials in Medicine, 12(1): 39-44
Siqueira, J.F., Rocas, I.N., Abad, E.C., Castro, A.J., Gahyva, S.M., Favieri, A. (2001) Ability of three root-end filling materials to prevent bacterial leakage. J Endod, 27(11): 673-5
Sirisha, K., Rambabu, T., Shankar, Y., Ravikumar, P. (2014) Validity of bond strength tests: A critical review: Part I. Journal of Conservative Dentistry, 17(4): 305
Stojanovska, V., Stevanović, M., Mitić, A. (2005) In vitro comparation of shear bond strength of two resin composite to enamel and dentine using Excite® as an adhesive. Acta stomatologica Naissi, vol. 21, br. 50, str. 429-436
Sudsangiam, S., Do, dentin N.R. (1999) bond strength tests serve a useful purpose. J Adhes Dent, 1(1); 57-67
Tedesco, T.K., Garcia, E.J., Soares, F.Z.M., Rocha, R.de O., Grande, R.H.M. (2013) Effect of Two Microshear Test Devices on Bond Strength and Fracture Pattern in Primary Teeth. Brazilian Dental Journal, 24(6): 605-609
Triana, R., Prado, C., Garro, J., García-Godoy, D.F. (1994) bond strength of fluoride-releasing materials. Am J Dent, 7(5); 252-4
van Meerbeek, B., Peumans, M., Poitevin, A., Mine, A., van Ende, A., Neves, A., de Munck, J. (2010) Relationship between bond-strength tests and clinical outcomes. Dental Materials, 26(2): e100-e121
van Meerbeek, B., Peumans, M., Poitevin, A., Mine, A., van Ende, A., Neves, A., de Munck, J. (2010) Relationship between bond-strength tests and clinical outcomes. Dental Materials, 26(2): e100-e121
van Meerbeek, B., de Munck, J., Yoshida, Y., Inoue, S., Vargas, M., Vijay, P., van Landuyt, K., Lambrechts, P., Vanherle, G. (2003) Buonocore memorial lecture. Adhesion to enamel and dentin: Current status and future challenges. Oper Dent, 28(3): 215-35
van Noort, R., Noroozi, S., Howard, I.C., Cardew, G. (1989) A critique of bond strength measurements. Journal of Dentistry, 17(2): 61-67
von Fraunhofer, J.A., Marshall, K.R., Holman, B.G. (2006) The effect of base ⁄ liner use on restoration leakage. Gen Dent, 54(2); 106-9