Article metrics

  • citations in SCindeks: [1]
  • citations in CrossRef:0
  • citations in Google Scholar:[=>]
  • visits in previous 30 days:0
  • full-text downloads in 30 days:0
article: 6 from 10  
Back back to result list
Srpski arhiv za celokupno lekarstvo
2005, vol. 133, iss. 5-6, pp. 297-302
article language: Serbian
document type: Paper
published on: 02/06/2007
doi: 10.2298/SARH0506297S
Thoracic electrical bioimpedance in the follow-up of patients with cardiovascular disorders
aClinical Center of Serbia, Clinic for Cardiology, Belgrade
bOpšta bolnica 'B. Orlandić', Bar
cUniversity of Belgrade, Faculty of Medicine, Institute of Hygiene and Medical Ecology

e-mail: bra@beotel.yu

Abstract

Thoracic electrical bioimpedance is a new non-invasive technique for obtaining haemodynamic parameters. The method involves the passing of low amperage, high frequency current through the thorax. The current induces a change of resistance within the thorax, which is registered by electrodes. The overall impedance of the thorax is a measure of the electrical resistance of the thorax to this high frequency, low amplitude current. In clinical practice, thoracic electrical bioimpedance has been applied in diagnostic, therapeutic, and prognostic use in patients with heart failure and hypertension, patients with pacemakers, within the scope of early diagnosis of implant rejection following heart transplantation, as well as in patients with kidney disorders, before and after dialysis. However, one of its most important applications is in the determination of antihypertensive therapy, because it provides the parameters that reflect the genesis of arterial blood pressure, in assessing these parameters, optimal therapy adjusted to the haemodynamic status of each patient can be prescribed.

Keywords

thoracic electrical bioimpedance; electrophysiology; heart failure; hypertension

References

Belardinelli, R., Ciampani, N., Costantini, C., Blandini, A., Purcaro, A. (1996) Comparison of impedance cardiography with thermodilution and direct Fick methods for noninvasive measurement of stroke volume and cardiac output during incremental exercise in patients with ischemic cardiomyopathy. Am J Cardiol, 77(15): 1293-301
Belojević, G., Stojanov, V., Jakovljević, B. (2003) Thoracic electrical bioimpedance monitoring of cardiovascular effects of noise. in: Prasher D. [ed.] Noise pollution and health, London: Noise Research Network Publications, str. 77-80
Belott, P. (1999) Bioimpedance in the pacemaker clinic. AACN Clin Issues, 10(3): 414-8
Buell, J.C. (1988) A practical, cost-effective, noninvasive system for cardiac output and hemodynamic analysis. Am Heart J, 116(2 Pt 2): 657-64
Campos, P.C., D'Cruz, I. (2004) Functional mitral regurgitation in decompensated heart failure: Combined bio-impedance and 2D echocardiography follow-up monitoring. Echocardiography, 21(4): 337-9
Chaney, J.C., Derdak, S. (2002) Minimally invasive hemodynamic monitoring for the intensivist: Current and emerging technology. Crit Care Med, 30(10): 2338-45
Chouhan, L. (2000) Electrical bioimpedance: A new noninvasive hemodynamic monitoring technique for clinical use. Heart Views, 1(8), str. 317-9
Christensen, T.B., Jensen, B.V., Hjerpe, J., Kanstrup, I.L. (2000) Cardiac output measured by electric bioimpedance compared with the CO2 rebreathing technique at different exercise levels. Clin Physiol, 20(2): 101-5
Critchley, L.A. (1998) Impedance cardiography. The impact of new technology. Anaesthesia, 53(7): 677-84
Hendrickson, K. (1999) Cost-effectiveness of noninvasive hemodynamic monitoring. AACN Clin Issues, 10(3): 419-24
Jewkes, C., Sear, J.W., Verhoeff, F., Sanders, D.J., Foex, P. (1991) Non-invasive measurement of cardiac output by thoracic electrical bioimpedance: A study of reproducibility and comparison with thermodilution. Br J Anaesth, 67(6): 788-94
Kubicek, W.G., Karnegis, J.N., Patterson, R.P., Witsoe, D.A., Mattson, R.H. (1966) Development and evaluation of an impedance cardiac output system. Aerosp Med, 37(12): 1208-12
Lasater, M. (1999) Managing inotrope therapy noninvasively. AACN Clin Issues, 10(3): 406-13
Lasater, M., von Rueden, K.T. (2003) Outpatient cardiovascular management utilizing impedance cardiography. AACN Clin Issues, 14(2): 240-50
Moshkovitz, Y., Kaluski, E., Milo, O., Vered, Z., Cotter, G. (2004) Recent developments in cardiac output determination by bioimpedance: Comparison with invasive cardiac output and potential cardiovascular applications. Curr Opin Cardiol, 19(3): 229-37
NYBOER.J. (1950) Electrical impedance plethysmography; a physical and physiologic approach to peripheral vascular study. Circulation, 2(6): 811-21
Osypka, M.J., Bernstein, D.P. (1999) Electrophysiologic principles and theory of stroke volume determination by thoracic electrical bioimpedance. AACN Clin Issues, 10(3): 385-99
Quail, A.W., Traugott, F.M., Porges, W.L., White, S.W. (1981) Thoracic resistivity for stroke volume calculation in impedance cardiography. J Appl Physiol, 50(1): 191-5
Sageman, W.S., Amundson, D.E. (1993) Thoracic electrical bioimpedance measurement of cardiac output in postaortocoronary bypass patients. Crit Care Med, 21(8): 1139-42
Sageman, W., Riffenburgh, R.H., Spiess, B.D. (2002) Equivalence of bioimpedance and thermodilution in measuring cardiac index after cardiac surgery. J Cardiothorac Vasc Anesth, 16(1): 8-14
Sramek, B.B. (1994) Thoracic electrical bioimpedance: Basic principles and physiologic relationship. Noninvas Cardiol, 3(2), str. 83-8
Stojanov, V., Avramović, D.M. (2000) Application of the thoracic electrical bioimpedance in the choice of antihypertensive therapy. in: Nedeljković S.I., Kanjuh V.I., Vukotić M.P. i dr. [ed.] Kardiologija, Beograd: Medicinski fakultet - Zavod za izdavačku delatnost, str. 642-5
Stojanov, V., Jakovljević, B., Avramović, M.D., Petrović, M. (1996) Significance of new non-invasive diagnostic procedures in the estimation of the efficiency of therapy with cilasaprile. in: Kardiovaskularna obolenja, ICN Galenika za medicinu, farmaciju i stomatologiju, 7: 60-5. (Serbian)
Stojanov, V., Avramović, D.M., Jakovljević, B., Kozarević, D., Janošević, S., Avramović, D.D. (1997) High-normal values of the arterial blood pressure as a risk factor for the occurrence of cardiovascular diseases. Jugoslovenski žurnal za hipertenziju, 1, str. 27-30
Strobeck, J.E., Silver, M.A., Ventura, H. (2000) Impedance cardiography: Noninvasive measurement of cardiac stroke volume and thoracic fluid content. Congest Heart Fail, 6(2): 56-9
Strobeck, J.E., Silver, M.A. (2004) Beyond the four quadrants: The critical and emerging role of impedance cardiography in heart failure. Congest Heart Fail, 10(2 Suppl 2): 1-6
Taler, S.J., Textor, S.C., Augustine, J.E. (2002) Resistant hypertension: Comparing hemodynamic management to specialist care. Hypertension, 39(5): 982-8
Tsadok, S. (1999) The historical evolution of bioimpedance. AACN Clin Issues, 10(3): 371-84
Weinhold, C., Reichenspurner, H., Fulle, P., Nollert, G., Reichart, B. (1993) Registration of thoracic electrical bioimpedance for early diagnosis of rejection after heart transplantation. J Heart Lung Transplant, 12(5): 832-6
Weiss, S.J., Ernst, A.A., Godorov, G., Diercks, D.B., Jergenson, J., Kirk, J. (2003) Bioimpedance-derived differences in cardiac physiology during exercise stress testing in low-risk chest pain patients. South Med J, 96(11): 1121-7
Yancy, C., Abraham, W.T. (2003) Noninvasive hemodynamic monitoring in heart failure: Utilization of impedance cardiography. Congest Heart Fail, 9(5): 241-50
Yung, G.L., Fedullo, P.F., Kinninger, K., Johnson, W., Channick, R.N. (2004) Comparison of impedance cardiography to direct Fick and thermodilution cardiac output determination in pulmonary arterial hypertension. Congest Heart Fail, 10(2 Suppl 2): 7-10
Ziegler, D., McReynolds, D., Webber, C., Eisenstein, C., Parker, W., Garcia, F. (2000) Comparison of the use of the pulmonary artery catheter versus thoracic electrical bioimpedance in a surgical intensive care unit (SICU). Crit Care Med, 28: A158