Metrika članka

  • citati u SCindeksu: 0
  • citati u CrossRef-u:0
  • citati u Google Scholaru:[=>]
  • posete u poslednjih 30 dana:4
  • preuzimanja u poslednjih 30 dana:3
članak: 8 od 19  
Back povratak na rezultate
Zaštita materijala
2017, vol. 58, br. 2, str. 243-248
jezik rada: srpski
vrsta rada: naučni članak
objavljeno: 22/06/2017
doi: 10.5937/ZasMat1702243S
Creative Commons License 4.0
Procjena sklonosti rashladne vode prema koroziji ili stvaranju inkrustacija u termoenergetskim postrojenjima
aRiTE Ugljevik, Ugljevik, BiH
bUniverzitet u Istočnom Sarajevu, Tehnološki fakultet, Zvornik, Republika Srpska, BiH
cPatenting, Beograd

Sažetak

Sklonost rashladne vode ka koroziji ili stvaranju inkrustacija se procjenjuje prema izračunatim indeksima: Langelier Saturation Index, Ryznar Stability Index, Larson-Skold Index i drugi. U ovom radu je dat osvrt na tendenciju rashladne vode u TE Ugljevik u kratkim intervalima tokom 2015. i 2016. godine.

Ključne reči

Reference

Casey, T.J. (2009) Water stabilisation and corrosion conrol. Aquavarra Research R&D Publications, Paper 2
Difilippo, M.N. (2006) Cooling tower water quality parameters for degraded water. California Energy Commission, PIER Final Project Report, p. 6-22
Đukić, B., Gligorić, M., Smiljanič, S. (2011) Priprema vode za industriju i energetiku. Zvornik: Tehnološki fakultet Zvornik, knjiga, p. 35-60
Gebbie, P. (2000) Water stability: What does it mean and how do you measure it. u: 63rd Annual Water Industry, Engineers and Operators' Conference Civic Centre-Warrnambool, p. 50-58
Keister, T. (2008) Cooling Water Management Basic Principles and Technology. Pennsylvania: American Institute of Chemists, Certified Water Technologist, Certificate 90; Distribution last version, 03/08, ( 3-32)
Leitz, F., Guerra, K. (2013) Water chemistry analysis for water conveyance, storage and desalination projects. Denver: Technical Service Center, p. 10-14
Palazzo, A., van der Merwe, J., Combrink, G. (2015) The accuracy of calcium-carbonate-based saturation indices in predicting the corrosivity of hot brackish water towards mild steel. J. S. Afr. INs. Min., 12-21; 115
Shams, M., Mohamadi, A., Sajadi, S.A. (2012) Evaluation of Corrosion and Scaling Potential of Water in RuralWater Supply Distribution Networks of Tabas, Iran. World Applied Sciences Journal, 17(11); 1484-1489
Shankar, B.S. (2014) Determination of Scaling and corrosion tendecies of water through the use of Langelier and Ryznar Indicies. Scholars Journal of Engineering and Technology, 123-127; 2A
Zia, K.M., Bhatti, H.N., Bhatti, I.A., Nawaz, R. (2008) A pHs Equation for Calcium Carbonate Scale Predoction in Cooling Water Systems. J. Chem. Soc. Pak., 30(2); 56-62