Experimental testing on phantom image for improved MRI compressed sensing
(naslov ne postoji na srpskom)
Keitaro DOO, Skopje, Macedonia

e-adresakrusty362472@yahoo.com
Ključne reči: Brain MRI; phantom test image; compressed sensing; parallel imaging; sampling patterns; wavelet transform; double-density wavelets; POCS; zero-filled; GRAPPA
Sažetak
(ne postoji na srpskom)
This paper presents a possible way for improving the techniques of compressed sensing and parallel imaging techniques for brain MRI. Experimental tests have been performed over a phantom test image. An exclusive elliptical sampling mask has been generated, which in combination with double-density wavelet transforms offers improvement over the standard approach. Additional tests undertaken as part of this research propose the usage of nonlinear reconstruction method, generated elliptical sampling mask and double-density wavelet transform for application of compressed sensing to brain MRI. An assessment of the results for diagnostic usage has been done by a specialist of radiology.
Reference
Adams, B.C. (2016) Investigation of sparsifying transforms in compressed sensing for magnetic resonance imaging with Fasttestc. Ph.D. dissertation
Cheng, J.Y., Zhang, T., Ruangwattanapaisarn, N., Alley, M.T., Uecker, M., Pauly, J.M., Lustig, M., Vasanawala, S.S. (2015) Free-breathing pediatric MRI with nonrigid motion correction and acceleration. Journal of Magnetic Resonance Imaging, 42(2), 407-420, August
Evladov, S., Levi, O., Stern, A. (2012) Progressive compressive imaging from Radon projections. Optics Express, 20(4), 4260
Kamilovski, A. (2018) Sampling mask and wavelet transform experimental testing for improved compressed sensing of brain MRI. Telfor
Lustig, M., Pauly, J.M. (2010) SPIRiT: Iterative self-consistent parallel imaging reconstruction from arbitrary k -space. Magnetic Resonance in Medicine, 64(2), 457-471
Lustig, M., Donoho, D., Santos, J., Paulu, J. (2008) A compressed sensing MRI. IEEE Signal Processing, March
Lustig, M., Donoho, D., Paulu, J. (2007) Sparse MRI: The application of compressed sensing for rapid Mr imaging. Magnetic Resonance in Medicine, December
Selesnick, I.W. (2001) The double density DWT. u: Petrosian A., Meyer F.G. [ur.] Wavelets in Signal and Image Analysis: From Theory to Practice, Boston, MA: Kluwer
Selesnick, I.W. (2004) The double-density dual-tree DWT. IEEE Transactions on Signal Processing, 52(5), 1304-1314
Selesnick, I.W., Abdelnour, F.A. (2004) Symmetric wavelet tight frames with two generators. Applied and Computational Harmonic Analysis, 17(2), 211-225, September
Wajer, F. (2001) Non-Cartesian MRI scan time reduction through sparse sampling. The Netherlands: Dept. Appl. Phys., Delft University of Technology, Ph.D. dissertation
Weizman, L., Eldar, Y.C. (2016) Reference-based Mr. Medical Physics Journal
 

O članku

jezik rada: engleski
vrsta rada: neklasifikovan
DOI: 10.5937/telfor2001018K
primljen: 17.06.2019.
revidiran: 22.12.2019.
prihvaćen: 23.12.2019.
objavljen: 31.07.2020.
objavljen u SCIndeksu: 09.10.2020.

Povezani članci

Nema povezanih članaka