2020, vol. 39, br. 1, str. 13-18
Merenje nivoa plazma feritina sa dve različite metode - poređenje Roche Cobas e601 sa Roche Cobas c501 (integrisani modularni sistem Roche Cobas 6000)
aGazi University, Amasya Central Public Health Laboratory, Medical Biochemistry, Turkey
bGazi University, Faculty of Medicine, Medical Biochemistry, Turkey

e-adresadurmus.ayan@gazi.edu.tr
Ključne reči: plazma feritin; elektrohemiluminescencija; imunoturbidimetrija
Sažetak
Uvod: Svrha ovog izučavanja je bila da se uporede nivoi plazma feritina bilo visoki ili niski u odnosu na referentne vrednosti određeni elektrohemiluminescencijom (ECLIA) i imunoturbidimetrijskom metodom i da se proceni da li mogu da se koriste prema potrebi. Metode: U proučavanja je uključeno 84 pacijenta sa visokom vrednošću feritina i 153 pacijenta sa niskom vrednošću u odnosu na referentne vrednosti. Uzorci plazme mereni su na Cobas e601 sa ECLIA metodom kao i imunotuirbidimetrijski na Cobas e501. Za poređenje je korišćen protokol CLSI EP9-A3. Takođe je primenjivana Passing-Bablok regresiona analiza i Spearman korelaciona analiza, dok je greška odstupanja između metoda (bias%) određivana Bland-Altmanovom analizom. Rezultati: Visoke i niske vrednosti feritina u plazmi izmerene na Cobas e601 modulu su poređene u odnosu na one dobijene na Cobas c501 modulu. Nađena je statistički značajna razlika (p < 0,001). Prema korelacionoj i regresionoj analizi (za niske nivoe plazma feritina; r = 0,993, p < 0,001, za visoke nivoe plazma feritina; r = 0,996, p < 0,001) metode su bile u saglasnosti jedna sa drugom. Dodadatno, vrednost bias% bila 10,4% za nizak nivo feritina u plazmi, a za visoke nivoe feritina u plazmi 12,6%. Zaključak: Shodno ovim istraživanja zaključujemo da su potrebna mnogo obimnija ispitivanja u prvom redu radi donošenja ispravnih kliničkih odluka a u vezi primene imunoturdidimetrijske metode integrisane sa ECLIA sistemom.
Reference
Blackmore, S., Hamilton, M., Lee, A., Worwood, M., Brierley, M., Heath, A., Thorpe, S.J. (2008) Automated immunoassay methods for ferritin: Recovery studies to assess traceability to an international standard. Clinical Chemistry and Laboratory Medicine, 46(10): 1450-1457
Carey, N.R., Anderson, P.F., George, H., Hartmann, A.E., Janzen, V.K., Kallner, A. (2006) User verification of performance for precision and trueness: Approved guideline. CLSI
Dignass, A., Farrag, K., Stein, J. (2018) Limitations of Serum Ferritin in Diagnosing Iron Deficiency in Inflammatory Conditions. International Journal of Chronic Diseases, 2018: 1-11
Dupuy, A.M., Debarge, L., Poulain, M., Badiou, S., Rossi, M., Cristol, J.P. (2009) Determination of serum ferritin using immunoturbidimetry or chemiluminescent detection in comparison with radioimmunoassay a compendium of a methodological juxtaposition. Clin Lab, 55(5-6): 207-222
Eisenga, M.F., Nolte, I.M., van der Meer, P., Bakker, S.J.L., Gaillard, C.A.J.M. (2018) Association of different iron deficiency cutoffs with adverse outcomes in chronic kidney disease. BMC Nephrology, 19(1): 225-225
Fielding, J., Cook, J., Bothwell, T., Crichton, R., Crosby, W., Dallman, P., et al. (1985) Proposed international standard of human ferritin for the serum ferritin assay. British Journal of Haematology, 61(1): 61-63
Garcia-Casal, M.N., Peña-Rosas, J.P., Urrechaga, E., Escanero, J.F., Huo, J., Martinez, R.X., Lopez-Perez, L. (2018) Performance and comparability of laboratory methods for measuring ferritin concentrations in human serum or plasma: A systematic review and meta-analysis. PLoS One, 13(5): e0196576-e0196576
Ince, F.D.E.H., Zeytinli, M., Avcı, R., Ozbek, D., Arı, M.E. (2016) Immunoturbidimetric and elevtrochemiluminescence methods for ferritin measurement. Turk Clin Biochem J, 14(1): 51-58
Karakochuk, C.D., Whitfield, K.C., Rappaport, A.I., Barr, S.I., Vercauteren, S.M., McLean, J., Hou, K., Talukder, A., Houghton, L.A., Bailey, K.B., Boy, E., Green, T.J. (2017) Comparison of four immunoassays to measure serum ferritin concentrations and iron deficiency prevalence among non-pregnant Cambodian women and Congolese children. Clinical Chemistry and Laboratory Medicine (CCLM), 55(1): 65-72
Lee, D.H., Kang, S.K., Choi, W.J., Kwak, K.M., Kang, D.K., Lee, S.H., Lee, J.H. (2018) Association between serum ferritin and hypertension according to the working type in Korean men: The fifth Korean National Health and nutrition examination survey 2010-2012. Annals of Occupational and Environmental Medicine, 30(1): 40-40
Lippi, G., Mattiuzzi, C. (2019) Project management in laboratory medicine. Journal of Medical Biochemistry, vol. 38, br. 4, str. 401-406
Milinković, N., Ignjatović, S., Šumarac, Z., Majkić-Singh, N. (2018) Uncertainty of measurement in laboratory medicine. Journal of Medical Biochemistry, vol. 37, br. 3, str. 279-288
Wang, W., Knovich, M.A., Coffman, L.G., Torti, F.M., Torti, S.V. (2010) Serum ferritin: Past, present and future. Biochimica et Biophysica Acta (BBA) - General Subjects, 1800(8): 760-769
Zhang, X., Lu, Y., Ma, L., Peng, Q., Qin, X., Li, S. (2015) A Comparison Study between Two Analyzers for Determining Serum Ferritin. Clinical Laboratory, 61(01+02/2015): 169-74
 

O članku

jezik rada: engleski
vrsta rada: izvorni naučni članak
PMC ID: PMC7282228
DOI: 10.2478/jomb-2018-0048
objavljen u SCIndeksu: 10.01.2020.
metod recenzije: dvostruko anoniman
Creative Commons License 4.0