Back povratak na rezultate
2021, vol. 19, br. 2, str. 448-465
Systematic assessment with "POE" method in office buildings cases study on the redesign results of office interior after occupied and operated
(naslov ne postoji na srpskom)
aUniversitas Pendidikan Indonesia, Faculty of Technology, Department of Architecture, Bandung, Indonesia
bUniversitas Katholik Parahyangan, Faculty of Engineering, Department of Architecture, Bandung, Indonesia
cInstitut Teknologi Nasional, Faculty of Engineering, Department of Architecture, Bandung, Indonesia

e-adresayudi.permana@upi.edu
Projekat:
LPPM UPI provided lecturer research grants in 2020

Ključne reči: in-door environment quality; workspace quality; officer performance; comfort and style of furniture; circulation; social space; flexibility
Sažetak
(ne postoji na srpskom)
This research is motivated by the fact that an office as a forum for activities depends on the type of business being carried out, where the conditions of the office will determine the credibility and synergy of a business entity, guaranteeing the performance and productivity of its employees. This study aims to formulate an interior design concept based on Post Occupancy Evaluation with the Mixed Methods Research (MMR) approach, which emphasizes the meaning of empiric based on relevant field data. The research method used the case study method with the MMR approach in data collection and analysis. The research step was started by analyzing the physical space conditions based on the design results that were compared with standardization, then a satisfaction survey was carried out using a questionnaire that was submitted to the employees as respondents. The MMR approach is intended to ensure the level of significance of the quality of the work environment in the room, the quality of the workplace, and the performance of employees. The research object is the Haleyora Powerindo office building, Jakarta. The results of the study show that the work environment quality is high and responds positively. According to the workplace quality, satisfaction is mainly related to workspace area and quality, comfort and style of furniture, circulation, and accessibility to the work table, effectiveness and efficiency of workplace layout, ICT implementation, and HVAC and maintenance. Social space and entertainment facilities provide flexibility in interacting between officers of different divisions that were not in the previous office. Based on the results of multiple regression calculations, the in-door environment and the officer workspace quality have a significant effect on officer performance. These are 3 main factors critical in conducting systematic evaluations to obtain results from office space design. This study is expected to be a strategic reference for planning and designing a similar spatial atmosphere in different locations or cases. Further research needs to be developed in the future on the ergonomic aspect through the human-centered design approach to obtain a single guideline for office design based on post-occupancy space performance and user participation.
Reference
*** (1990) Indian Health Service Hospital Browning Montana Facility Post Occupancy Evaluation. DTI-Division of Health Facilities Planning (DHFP)-Office of Management-Office of Resource Management
*** (2005) Post Occupancy Evaluation: Braes High School, Falkirk. Edinburgh: Scottish Executive, See
*** (2003) Design Guidance: Office Space. Division of the University Architect
Abbaszadeh, S., Zagreus, L., Lehrer, D., Huizenga, C. (2006) Occupant satisfaction with indoor environmental quality in green buildings. u: Proc. Heal. Build. Lisbon, Purtugal, 365-370
Akman, E. (2002) Post Occupancy Evaluation With Building Values Approach. Bilkent University
Aksah, H., Nawawi, A.H., Hashim, A.E., Dewiyana, E. (2016) Assessing Score of Applicability and Importance on Functional Performance Criteria for Historical Building. Procedia - Social and Behavioral Sciences, 222: 65-74
Al-Anzi, N.M. (2009) Workplace environment and its impact on employee performance. Malaysia: Open University of Malaysia
Al-Ghriybah, M., Fadhli, Z.M., Hissein, D.D., Mohd, S. (2019) Wind energy assessment for the capital city of Jordan, Amman. Journal of Applied Engineering Science, vol. 17, br. 3, str. 311-320
Aliyu, A.A., Muhammad, M.S., Bukar, M.G., Singhry, I.M. (2016) An Evaluation of Occupants' Satisfaction and Comfort with Housing Facilities: Literature Analysis and Future. u: Acad. Conf. Agenda Sub-Sahara Africa, Proc
Alubaid, F.A.-R. S., Alhadeethi, R.H. F., Mohamed, A.J. (2020) Assessment: The safety policy management for building construction companies in Jordan. Journal of Applied Engineering Science, vol. 18, br. 1, str. 120-131
Antikainen, R., Lappalainen, S., Lönnqvist, A., Maksimainen, K., Reijula, K., Uusi-Rauva, E. (2008) Exploring the relationship between indoor air and productivity. Scand J Work Environ Heal Suppl, (4):79-82
Armiati (2015) Meningkatkan Efektivitas Kerja Pegawai Melalui Penataan Layout Kantor. u: Semin. Nas. Ekon. Manaj. DAN Akunt. Fak. Ekon. Univ. NEGERI PADANG
Bashir, I., Hamid, B., Jhanjhi, N.Z., Humayun, M. (2020) Systematic Literature Review and Empirical Study for Success Factors: Client and Vendor Perspective. J Eng Sci Technol, 15(4): 2781-2808
Burroughs, H.E., Hansen, S.J. (2011) Managing indoor air quality. Lilburn, GA: Fairmont Press, Inc, 5th ed
Carthey, J. (2006) Post Occupancy Evaluation: Development of a Standardised Methodology for Australian Health Projects. International Journal of Construction Management, 6(1): 57-74
Choi, J., Lee, K. (2018) Investigation of the feasibility of POE methodology for a modern commercial office building. Building and Environment, 143: 591-604
Choi, J.H., Loftness, V., Aziz, A. (2012) Post-occupancy evaluation of 20 office buildings as basis for future IEQ standards and guidelines. Energy and Buildings, 46: 167-175
Clements-Croome, D., Turner, B., Pallaris, K. (2019) Flourishing workplaces: A multisensory approach to design and POE. Intelligent Buildings International, 11(3-4): 131-144
Creswell, J.W. (2010) Research Design: Pendekatan Kualitatif, Kuantitatif, dan Mired. Yogyakarta: Pustaka Pelajar
Danielsson, C.B. (2008) Differences in perception of noise and privacy in different office types. u: Eur. Conf. Noise Control. Paris, France, Proc, 531-536
Davies, H. (2010) The psychological and physical needs of workers impacting office design. u: COBRA 2010: Constr. Build. Real Estate Res. Conf. R. Inst. Chart. Surv. COBRA, London, England, pp 1-15
de Carli, M., de Giuli, V. (2009) Optimization of daylight in buildings to save energy and to improve visual comfort: Analysis in different latitudes. Int Build Perform Simul Assoc (IBPSA), 2009 :1797-1805
Desmonda, A.A. (2016) Pengaruh Lingkungan Kerja Fisik Terhadap Produktivitas Kerja Karyawan Pada Pt. Federal International Finance Cabang Samarinda. Ejuornal Adm Bisnis, 4(4): 1-15
Emuze, F., Mashili, H., Botha, B. (2013) Post-occupancy evaluation of office buildings in a Johannesburg country club estate. Acta Structilia, 20(1): 89-110
Environmental Protection Agency (EPA) (1974) Information On Levels And Environmental Noise Requisite To Protect Public Health And Welfare With And Adequate Margin Of Safety. Washington, DC
Friedman, A., Zimring, C., Zube, C. (1978) Environmental Design Evaluation. New York, NY: Plenum
Gie, T.L. (2000) Modern Office Administration. Yogyakarta: Liberty
Goudarzvandchegini, M., Modaberei, M. (2011) The impact of office layout on productivity of selected organizations in Gilan-Iran. J Trends Adv Sci Eng, 2(1): 73-80
Green, K., Lopez, M., Wysocki, A., Kepner, K., Farnsworth, D., Clark, J.L. (2015) Diversity in the Workplace: Benefits, Challenges, and the Required Managerial Tools. 1
Groat, L., Wang, D. (2002) Wiley Encyclopedia of Molecular Medicine. Canada: John Wiley & Sons, Inc
Hadjri, K., Crozier, C. (2009) Post-occupancy evaluation: purpose, benefits and barriers. Facilities, 27(1/2): 21-33
Hay, R., Samuel, F., Watson, K.J., Bradbury, S. (2018) Post-occupancy evaluation in architecture: Experiences and perspectives from UK practice. Building Research & Information, 46(6): 698-710
Hermawan, H., Hadiyanto, H., Sunaryo, S., Kholil, A. (2019) Analysis of thermal performance of wood and exposed stone-walled buildings in mountainous areas with building envelop variations. Journal of Applied Engineering Science, vol. 17, br. 3, str. 321-332
Hewitt, D., Higgins, C. (2005) A Market-Friendly Post-Occupancy Evaluation: Building Performance Report 97204
Hongisto, V. (2008) Effects of sound masking on workers: A case study in a landscaped office. u: 9th Int Congr Noise as a Public Heal Probl, (1979):1-8
Kong, Z., Utzinger, M.D., Freihoefer, K., Steege, T. (2018) The impact of interior design on visual discomfort reduction: A field study integrating lighting environments with POE survey. Building and Environment, 138: 135-148
Kooymans, R., Haylock, P. (2006) Post occupancy evaluation and workplace productivity. u: PRRES Conf :15
Lackney, J.A., Zajfen, P. (2005) Post-occupancy evaluation of public libraries: Lessons learned from three case studies. Libr Adm Manag, 19(1): 16-25
Lee, J., Wargocki, P., Chan, Y., Chen, L., Tham, K. (2020) How does indoor environmental quality in green refurbished office buildings compare with the one in new certified buildings?. Building and Environment, 171: 106677
Li, H., Ng, T.S., Skitmore, M. (2018) Stakeholder impact analysis during post-occupancy evaluation of green buildings: A Chinese context. Building and Environment, 128(November 2017):89-95
Liang, X., Hong, T., Shen, G.Q. (2016) Occupancy data analytics and prediction: A case study. Building and Environment, 102: 179-192
Liang, X., Peng, Y., Shen, G.Q. (2016) A game theory based analysis of decision making for green retrofit under different occupancy types. Journal of Cleaner Production, 137: 1300-1312
Manahasa, O., Özsoy, A., Manahasa, E. (2020) Evaluative, inclusive, participatory: Developing a new language with children for school building design. Building and Environment, 188: 107374
Marlow, C.R. (2010) Research methods for generalist social works. Belmont, CA: Cengage Learning, 5th editio
Mcgrath, P.T., Horton, M. (2011) A post-occupancy evaluation (POE) study of student accommodation in an MMC/modular building. Structural Survey, 29(3): 244-252
Moekijat (2002) Office Management. Bandung: Mandar Maju
Moleong, L.J. (2008) Qualitative Research Methodology. Bandung: Remaja Rosdakarya Offset
Mumovic, D., Davies, M., Ridley, I., Altamirano-Medina, H., Oreszczyn, T. (2009) A methodology for post-occupancy evaluation of ventilation rates in schools. Building Services Engineering Research and Technology, 30(2): 143-152
Ornstein, S., Ono, R., Gill, A., Machry, H. (2007) Health Care Architecture in Sao Paulo, Brazil: Evaluating Accessibility and Fire Safety in Large Hospitals. Archnet-IJAR, 1(1): 13-25
Pahomova, E.G., Monastyrev, P.V., Mishchenko, E.S., Yezerskiy, V., Ivanov, I.A., Balthazar, A.D. (2019) House-building analysis when using additive technologies: Classification, advantages and disadvantages. Journal of Applied Engineering Science, vol. 17, br. 4, str. 449-456
Pastore, L., Andersen, M. (2019) Building energy certification versus user satisfaction with the indoor environment: Findings from a multi-site post-occupancy evaluation (POE) in Switzerland. Building and Environment, 150(January):60-74
Permana, A.Y., Akbardin, J., Permana, A.F.S., Nurrahman, H. (2020) The concept of optimal workplace in providing a great experience to improve work professionalism in the interior design of pln Corporate university, Ragunan, Jakarta. Int J Adv Sci Technol, 29(7): 3238-3254
Preiser, W.F., Vischer, J.C. (2005) Assessing Building Performance. Assess Build Perform
Preiser, W.F., Rabinowitz, H.Z., White, E.T. (1988) Post-Occupancy Evaluation. New York: Van Nostrand Reinhold
Preiser, W.F.E., Vischer, J., Zimring, C., Rosenheck, T., Kaplan, A. (2001) The Evolution of Post-Occupancy Evaluation: Toward Building Performance and Universal Design Evaluation. Fed Facil Counc Ed Learn from our Build, (145): 138
Preiser, W.F.E., Nasar, J.L. (2007) Assessing Building Performance: Its Evolution From Post-Occupancy Evaluation. Archnet-IJAR -Int J Archit Res, 2(1): 84-99
PT. Indonesia Power (2018) Keputusan Direksi Nomor 39.K/010/IP/2018 tentang Pedoman Pengendalian Gratifikasi di PT Indonesia Power. 1-19
Putra, B.G.A., Madyono, G. (2017) Analisis Intensitas Cahaya Pada Area Produksi Terhadap Keselamatan Dan Kenyamanan Kerja Sesuai Dengan Standar Pencahayaan. OPSI: Jurnal Optimasi Sist Ind, 10(2):115
QHRS (2001) Royal Children's Hospital Post Occupancy Evaluation
Quible, Z.K. (2004) Administrative Office Management: An Introduction. Edinburgh Gate, Harlow: Pearson Education Limited, eighth
Rhino Interior Group (2017) Office interior design: An intelligent approach. United Kingdom, Guide 2
Riba, R.S.G. (1991) A Research Report for the Architectural Profession. u: Duffy F.W. [ur.] Architectural Knowledge: The Idea of a Profession, London: E. & F.N. Spon
Riley, M., Kokkarinen, N., Pitt, M. (2010) Assessing post occupancy evaluation in higher education facilities. Journal of Facilities Management, 8(3): 202-213
Rimantho, D., Cahyadi, B. (2015) Analisis Kebisingan Terhadap Karyawan Di Lingkungan Kerja Pada Beberapa Jenis Perusahaan. J Teknol, 7(1): 21-27
Saberi, O. (2009) Thermal comfort and green buildings. u: WSP Environ. Energy (Middle East): Green Retrofit Conf. Dubai, United Arab Emirates, Proc, 1-20
Samani, S.A. (2011) The influence of light on student's learning performance in learning environments: A knowledge internalization perspective. World Acad Sci Eng Technol, 81(September 2011):540-547
Sanders, M.S., Mccormick, E.J. (1987) Human factors in engineering and design. Singapore: Mcgraw-Hill Book Company, 6th ed
Sant'anna, D.O., Dos, S.P.H., Vianna, N.S., Romero, M.A. (2018) Indoor environmental quality perception and users' satisfaction of conventional and green buildings in Brazil. Sustain Cities Soc, 43: 95-110
Shepley, M.M., Zimmerman, K.N., Boggess, M.M., Lee, Y.J. (2009) Architectural Office Post-Occupancy Evaluation. Journal of Interior Design, 34(3): 17-29
Stevenson, F. (2019) Embedding building performance evaluation in UK architectural practice and beyond. Building Research & Information, 47(3): 305-317
Sukoco, M.B. (2007) Modern Office Administration Management. Jakarta: Erlangga
Syafriyani,, Sangkertadi,, Waani, J.O. (2015) Evaluasi Purna Huni (Eph): Aspek Perilaku Ruang Dalam SLB YPAC Manado. Eval Purna Huni Aspek Perilaku Ruang Dalam Slb Ypac Manad, 12(3): 1-13
Tang, H., Ding, Y., Singer, B.C. (2020) Post-occupancy evaluation of indoor environmental quality in ten nonresidential buildings in Chongqing, China. Journal of Building Engineering, 32: 101649
Tanyer, A.M., Pembegül, T. (2010) Post Occupancy Evaluation in the Practice of Architecture: A Case Study of Lütfi Kırdar Convention and Exhibition Centre. METU Journal of Faculty of Architecture, 27(1): 241-265
Vischer, J.C. (2008) The Concept of Workplace Performance and Its Value to Managers. Berkeley: Univ California, 49(2):1-18
Vischer, J.C. (2008) Towards an Environmental Psychology of Workspace: How People are Affected by Environments for Work. Architectural Science Review, 51(2): 97-108
Walker, K. (2011) Developing a site evaluation framework for ephemeral festivals and events: A study of Hillside Festival. Guelph, Canada: University of Guelph
Wang, L., Zheng, D. (2020) Integrated analysis of energy, indoor environment, and occupant satisfaction in green buildings using real-time monitoring data and on-site investigation. Building and Environment, 182: 107014
Watson, C., Thomson, K. (2005) Bringing Post-occupancy Evaluation to Schools in Scotland. Eval Qual Educ Facil, 129-134
Wu, S.R., Greaves, M., Chen, J., Grady, S.C. (2017) Green buildings need green occupants: A research framework through the lens of the Theory of Planned Behaviour. Architectural Science Review, 60(1): 5-14
Wu, X., Lin, B., Papachristos, G., Liu, P., Zimmermann, N. (2020) A holistic approach to evaluate building performance gap of green office buildings: A case study in China. Build Environ
Xiong, Y., Krogmann, U., Mainelis, G., Rodenburg, L.A., Andrews, C.J. (2015) Indoor air quality in green buildings: A case-study in a residential high-rise building in the northeastern United States. Journal of Environmental Science and Health, Part A: Toxic/Hazardous Subst Environ Eng, 50(3): 225-242
Yezhov, V.S., Semicheva, N.E., Pahomova, E.G., Bredikhina, N.V., Emmanuel, S. (2019) To the question of improving energy-saving and environmental characteristics of urban buildings. Journal of Applied Engineering Science, vol. 17, br. 4, str. 550-554
Yin, R.K. (2018) Case study research and applications: Design and methods. Los Angeles: Sage Publication, 6th ed
Yin, R.K. (2012) Applications of case study research. CA: Sage, 3rd ed
Zimmerman, A., Martin, M. (2001) Post-occupancy evaluation: Benefits and barriers. Building Research & Information, 29(2): 168-174
 

O članku

jezik rada: engleski
vrsta rada: izvorni naučni članak
DOI: 10.5937/jaes0-28072
primljen: 20.08.2020.
prihvaćen: 13.11.2020.
objavljen u SCIndeksu: 07.09.2021.
metod recenzije: dvostruko anoniman
Creative Commons License 4.0

Povezani članci

Nema povezanih članaka